Users must consult the listed agency s documentation for complete information.
One hour fire rated roof assembly.
Fire resistance ratings are expressed in the number of minutes or hours a structure can withstand a fire simulation test.
Keep in mind that most of the wood truss fire rated assemblies call for a minimum depth of 12 in.
Truss technology in building figure 1.
Do the plans call for a 1 hour assembly or a 2 hour assembly.
The following tables are only summaries of the fire rated assembly reports.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Sheathing on both sides.
Elements of buildings the fire resistance rating classifies the ability of an assembly to confine and isolate fire within a zone comprised of fire resistance rated walls ceiling and floor assemblies.
3 mineral wool batts.
Fire resistance ratings time temperature include structural elements and everything above including the roof membrane and its surfacing.
2 fire rated wood frame wall and floor ceiling assemblies.
According to the engineered wood association a one hour rating indicates that a wall constructed in a manner similar to the one tested will contain flames and high temperatures and support its full load for at least one hour after the fire begins.
A one hour rating would mean the structural elements have not yet reached their yield point when exposed to a under deck heat load defined in astm e119 for steel structural members as reaching 1 070 degrees f.
5 8 type x gypsum wallboard h 2 6 type s drywall screws 12 o c.
With 1 2 wood structural panels with.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
Test reports are available from reporting agencies or wtca where indicated.
Fire safety caution passing a fire test in a controlled laboratory setting and or certifying or labeling a product as having a one hour two hour or any other fire resistance or protection rating and therefore as acceptable for use in certain fire rated assemblies systems does not mean that either a particular assembly system.
Assemblies rated from both sides.
Wood joists wood i joists floor trusses and flat or pitched roof trusses spaced a maximum 24 o c.
The ratings relate to fire tests designed to determine how quickly fire can raise the temperature to unacceptable levels.
Generic fire rated assembly listing construction elements 1 5 hr rating 1.
Table 1 one hour fire rated loadbearing wood frame wall assemblies.